Prosonic FDU9x FDU95
Brand: Endress+HauserProsonic FDU9x FDU95
Brand: Endress+Hauser
Extended Specs at a Glance
Main wetted parts:
UP (unsaturated polyester)
Process temperature:
-40 °C ... 80 °C
or 150 °C
(-40 °F ... 176 °F
or 302 °F)
or 150 °C
(-40 °F ... 176 °F
or 302 °F)
Max. measurement distance:
45 m (148 ft)
Accuracy:
+/- 2mm + 0.17% of measured distance
Process pressure / max. overpressure limit:
0.7 bar...1.5 bar abs
(10 psi...22 psi)
(10 psi...22 psi)
Field of application
The FDU95 ultrasonic sensor for continuous, non-contact and maintenance-free level measurement of powdery to coarse bulk materials. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of sensors. Suited for explosion hazardous areas. Maximum measuring range in solids 45m (148ft).
Key Benefits
- Integrated temperature sensor for Time-of-Flight correction. Accurate measurements are possible, even if temperature changes are present
- Suited for rough ambient conditions thanks to separate installation from the transmitter (up to 300m)
- Reduced build-up formation because of the self-cleaning effect
- Integrated automatic sensor detection for transmitters FMU90/FMU95 for simple commissioning
- Weather resistant and flood-proof (IP 68)
Specifications
Brand
Industry
- Chemical
- Power & Energy
- Mining, Minerals & Metals
Product Family
- Prosonic
Continuous / Liquids
Characteristic / Application
- Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300 m in-between sensor and transmitter
Supply / Communication
- 4-wire (HART, PROFIBUS DP)
Accuracy
- +/- 2 mm + 0.17% of measured distance
Ambient temperature
- -40 °C...80 °C
- or 150 °C,
- (-40 °F...176 °F
- or 302 °F)
Process temperature
- -40 °C...80 °C
- or 150 °C,
- (-40 °F...176 °F
- or 302 °F)
Process pressure / max. overpressure limit
- 0.7 bar...1.5 bar abs
- (10 psi...22 psi)
Main wetted parts
- UP (unsaturated polyester)
Process connection
- G / NPT 1"
Blocking distance
- 0.7 m / 80 °C,
- (2.3 ft / 176 °F),
- 0.9 m / 150 °C,
- (2.9 ft / 302 °F)
Max. measurement distance
- 45 m (148 ft)
Communication
- Transmitter:
- 4...20 mA HART
- PROFIBUS DP
Certificates / Approvals
- ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI,UK Ex
Options
- Second 4...20 mA output
Components
- Transmitter:
- FMU90, FMU95
Continuous / Solids
Characteristic / Application
- Separated version with field housing or top hat rail housing for control cabinet instrumentation, 300m in-between sensor and transmitter
Supply / Communication
- 4-wire (HART, PROFIBUS DP)
Accuracy
- +/- 2mm + 0.17% of measured distance
Ambient temperature
- -40 °C ... 80 °C
- or 150 °C
- (-40 °F ... 176 °F
- or 302 °F)
Process temperature
- -40 °C ... 80 °C
- or 150 °C
- (-40 °F ... 176 °F
- or 302 °F)
Process pressure / max. overpressure limit
- 0.7 bar...1.5 bar abs
- (10 psi...22 psi)
Main wetted parts
- UP (unsaturated polyester)
Process connection
- G / NPT 1"
Blocking distance
- 0.7 m / 80 °C
- (2.3 ft / 176 °F)
- 0.9 m / 150 °C
- (2.9 ft / 302 °F)
Max. measurement distance
- 45 m (148 ft)
Communication
- Transmitter:
- 4 ... 20 mA HART
- PROFIBUS DP
Certificates / Approvals
- ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, UK Ex
Options
- Second 4...20mA output
Components
- Transmitter:
- FMU90