ORP Sensors & Transmitters

Products for effective ORP measurement in all industries.

1 - 48 of 51 Products
Transmitter Liquiline, 4-wire CM442
Endress+Hauser
Transmitter Liquiline, 4-wire CM442
Extended Extended
Request Information
Liquiline, 4-wire CM448
Endress+Hauser
Liquiline, 4-wire CM448
Extended Extended
Request Information
Liquiline, 4-wire CM442R
Endress+Hauser
Liquiline, 4-wire CM442R
Extended Extended
Request Information
Liquiline, 4-wire CM444
Endress+Hauser
Liquiline, 4-wire CM444
Extended Extended
Request Information
pH/ORP sensor Memosens CPS96E
Endress+Hauser
pH/ORP sensor Memosens CPS96E
Extended Extended
Request Information
Dipfit CPA111
Endress+Hauser
Dipfit CPA111
Request Information
Memosens CPS42E
Endress+Hauser
Memosens CPS42E
Request Information
Orbipac CPF82
Endress+Hauser
Orbipac CPF82
Request Information
Ceraliquid CPS42D
Endress+Hauser
Ceraliquid CPS42D
Request Information
Flowfit CYA21
Endress+Hauser
Flowfit CYA21
Request Information
Memosens CPS76E
Endress+Hauser
Memosens CPS76E
Extended Extended
Request Information
pH buffer Buffer solution CPY20
Endress+Hauser
pH buffer Buffer solution CPY20
Request Information
Memosens CPS16E
Endress+Hauser
Memosens CPS16E
Extended Extended
Request Information
Flowfit CPA25
Endress+Hauser
Flowfit CPA25
Lean Lean
Request Information
Orbipac CPF82D
Endress+Hauser
Orbipac CPF82D
Request Information
Liquiline, 4-wire CM44P
Endress+Hauser
Liquiline, 4-wire CM44P
Extended Extended
Request Information
Transmitter Liquiline, 2-wire CM42
Endress+Hauser
Transmitter Liquiline, 2-wire CM42
Extended Extended
Request Information
In-line Photometer CYA680
Endress+Hauser
In-line Photometer CYA680
Request Information
Transmitter Liquiline, 2-wire CM82
Endress+Hauser
Transmitter Liquiline, 2-wire CM82
Request Information
Liquiline, 4-wire CM448R
Endress+Hauser
Liquiline, 4-wire CM448R
Extended Extended
Request Information
Transmitter Liquiline, 4-wire CM14
Endress+Hauser
Transmitter Liquiline, 4-wire CM14
Fundamental Fundamental
Request Information
Liquisys CPM253
Endress+Hauser
Liquisys CPM253
Request Information
Flowfit CYA27
Endress+Hauser
Flowfit CYA27
Request Information
Liquiline, 4-wire CM444R
Endress+Hauser
Liquiline, 4-wire CM444R
Extended Extended
Request Information
Liquiline, 4-wire CYY7
Endress+Hauser
Liquiline, 4-wire CYY7
Extended Extended
Request Information
Flowfit CPA240
Endress+Hauser
Flowfit CPA240
Request Information
Ceragel CPS72D
Endress+Hauser
Ceragel CPS72D
Request Information
Ceragel CPS72
Endress+Hauser
Ceragel CPS72
Request Information
Cleanfit CPA871
Endress+Hauser
Cleanfit CPA871
Request Information
Flexdip CYH112
Endress+Hauser
Flexdip CYH112
Request Information
Memosens CPS62E
Endress+Hauser
Memosens CPS62E
Extended Extended
Request Information
Flexdip CYA112
Endress+Hauser
Flexdip CYA112
Request Information
Memosens CPF82E
Endress+Hauser
Memosens CPF82E
Extended Extended
Request Information
Cleanfit CPA875
Endress+Hauser
Cleanfit CPA875
Request Information
Liquiline Control CDC90
Endress+Hauser
Liquiline Control CDC90
Request Information
Orbisint CPS12D
Endress+Hauser
Orbisint CPS12D
Request Information
Memosens CPS92E
Endress+Hauser
Memosens CPS92E
Extended Extended
Request Information
Memosens CPS72E
Endress+Hauser
Memosens CPS72E
Extended Extended
Request Information
Liquisys CPM223
Endress+Hauser
Liquisys CPM223
Request Information
Cleanfit CPA472D
Endress+Hauser
Cleanfit CPA472D
Request Information
Ecofit CPA640
Endress+Hauser
Ecofit CPA640
Request Information
Cleanfit CPA450
Endress+Hauser
Cleanfit CPA450
Request Information
Cleanfit CPA474
Endress+Hauser
Cleanfit CPA474
Request Information
Cleanfit CPA473
Endress+Hauser
Cleanfit CPA473
Request Information
Unifit CPA842
Endress+Hauser
Unifit CPA842
Request Information
Multi parameter measuring device Hand held CML18
Endress+Hauser
Multi parameter measuring device Hand held CML18
Lean Lean
Request Information
Dipfit CPA140
Endress+Hauser
Dipfit CPA140
Request Information
Redox sensor Memosens CPS12E
Endress+Hauser
Redox sensor Memosens CPS12E
Extended Extended
Request Information

ORP Sensors & Transmitters

ORP (oxidation-reduction potential) sensors and transmitters measure the redox potential of a solution, providing a compact indicator of oxidative or reductive conditions. ORP is widely used as a process control surrogate where direct measurement of every reacting species is impractical. The category is positioned for effective ORP measurement across industries, supporting chemical dosing strategies and confirming that a desired oxidation or reduction environment has been achieved.

ORP measurement systems typically pair glass-electrode sensors (including ORP-only and combined pH/ORP designs) with transmitters that provide signal conditioning, diagnostics, and standardized outputs. Product families include Memosens and Liquiline offerings, enabling consistent installation concepts, digital sensor handling, and broad communications support. Proper assemblies and mounting hardware are important to maintain stable immersion and minimize noise, coating effects, and reference instability over time.

Benefits are centered on control simplification and response speed. ORP provides a real-time feedback variable for oxidant and reductant dosing, supporting tighter control of disinfection, dechlorination, and redox-driven treatment reactions. Stable ORP control can reduce chemical consumption, improve process consistency, and provide early warning of upstream disturbances or mixing problems. Trending also supports optimization efforts, since ORP changes often precede more visible downstream symptoms such as odor formation or poor settling.

Common applications include wastewater disinfection/dechlorination control, advanced oxidation processes, cyanide destruction, chromium reduction, and anaerobic/aerobic zone control in biological treatment. ORP is also used in industrial reaction control where oxidation state impacts product quality, such as certain bleaching and chemical synthesis steps. In water reuse and industrial water systems, ORP can complement residual disinfectant measurement to provide a broader view of oxidative treatment conditions.

Implementation considerations include choosing electrode materials appropriate for the chemistry, ensuring consistent immersion and flow at the measurement point, and planning for cleaning strategies where fouling is expected. Reference system stability and electrical grounding practices influence signal quality, especially in mixed-metal piping or high-noise environments. Transmitter selection often centers on multi-parameter capability, diagnostics, and communications needed to standardize control integration and maintenance workflows.

Field Instruments & Controls, Inc. an exclusive authorized representative of sales and service for Endress+Hauser.