Oxygen Sensors & Transmitters

Products for high accuracy oxygen measurement in all industries.

1 - 47 of 47 Products
Oxymax COS41
Endress+Hauser
Oxymax COS41
Request Information
Transmitter Liquiline, 4-wire CM442
Endress+Hauser
Transmitter Liquiline, 4-wire CM442
Extended Extended
Request Information
Liquiline, 4-wire CM448
Endress+Hauser
Liquiline, 4-wire CM448
Extended Extended
Request Information
Oxymax COS61
Endress+Hauser
Oxymax COS61
Request Information
Liquiline, 4-wire CM442R
Endress+Hauser
Liquiline, 4-wire CM442R
Extended Extended
Request Information
Liquiline, 4-wire CM444
Endress+Hauser
Liquiline, 4-wire CM444
Extended Extended
Request Information
Memobase CYZ71D
Endress+Hauser
Memobase CYZ71D
Request Information
Hand held CYM290
Endress+Hauser
Hand held CYM290
Request Information
Flowfit CYA21
Endress+Hauser
Flowfit CYA21
Request Information
Flowfit CPA25
Endress+Hauser
Flowfit CPA25
Lean Lean
Request Information
Assembly CYA251
Endress+Hauser
Assembly CYA251
Request Information
Digital measuring cable Measuring cable CYK10
Endress+Hauser
Digital measuring cable Measuring cable CYK10
Request Information
Liquiline, 4-wire CM44P
Endress+Hauser
Liquiline, 4-wire CM44P
Extended Extended
Request Information
Transmitter Liquiline, 2-wire CM42
Endress+Hauser
Transmitter Liquiline, 2-wire CM42
Extended Extended
Request Information
Chemoclean CYR10B
Endress+Hauser
Chemoclean CYR10B
Request Information
Converter CYM17
Endress+Hauser
Converter CYM17
Request Information
Transmitter Liquiline, 2-wire CM82
Endress+Hauser
Transmitter Liquiline, 2-wire CM82
Request Information
Liquiline, 4-wire CM448R
Endress+Hauser
Liquiline, 4-wire CM448R
Extended Extended
Request Information
Flowfit COA250
Endress+Hauser
Flowfit COA250
Request Information
Memocheck CYP02E
Endress+Hauser
Memocheck CYP02E
Request Information
Oxygen sensor Oxymax COS61D
Endress+Hauser
Oxygen sensor Oxymax COS61D
Extended Extended
Request Information
Digital measuring cable Memobase CYK20
Endress+Hauser
Digital measuring cable Memobase CYK20
Request Information
Transmitter Liquiline, 4-wire CM14
Endress+Hauser
Transmitter Liquiline, 4-wire CM14
Fundamental Fundamental
Request Information
Flowfit CYA27
Endress+Hauser
Flowfit CYA27
Request Information
Liquiline, 4-wire CM444R
Endress+Hauser
Liquiline, 4-wire CM444R
Extended Extended
Request Information
Liquiline, 4-wire CYY7
Endress+Hauser
Liquiline, 4-wire CYY7
Extended Extended
Request Information
Liquisys COM253
Endress+Hauser
Liquisys COM253
Request Information
Hand held CYM291
Endress+Hauser
Hand held CYM291
Request Information
Oxygen sensor Memosens COL37E
Endress+Hauser
Oxygen sensor Memosens COL37E
Request Information
Cleanfit COA451
Endress+Hauser
Cleanfit COA451
Request Information
Cleanfit CPA871
Endress+Hauser
Cleanfit CPA871
Request Information
Zero point gel Miscellaneous COY8
Endress+Hauser
Zero point gel Miscellaneous COY8
Request Information
Liquisys COM223
Endress+Hauser
Liquisys COM223
Request Information
Flexdip CYH112
Endress+Hauser
Flexdip CYH112
Request Information
Oxygen sensor Memosens COS81E
Endress+Hauser
Oxygen sensor Memosens COS81E
Extended Extended
Request Information
Flexdip CYA112
Endress+Hauser
Flexdip CYA112
Request Information
Cleanfit CPA875
Endress+Hauser
Cleanfit CPA875
Request Information
Memocheck CYP03D
Endress+Hauser
Memocheck CYP03D
Request Information
Measuring cable CYK11
Endress+Hauser
Measuring cable CYK11
Request Information
Memosens COS51E
Endress+Hauser
Memosens COS51E
Extended Extended
Request Information
Oxygen sensor Memosens COS22E
Endress+Hauser
Oxygen sensor Memosens COS22E
Extended Extended
Request Information
Ecofit CPA640
Endress+Hauser
Ecofit CPA640
Request Information
Cleanfit CPA450
Endress+Hauser
Cleanfit CPA450
Request Information
Unifit CPA842
Endress+Hauser
Unifit CPA842
Request Information
Multi parameter measuring device Hand held CML18
Endress+Hauser
Multi parameter measuring device Hand held CML18
Lean Lean
Request Information
Topclean CYC25
Endress+Hauser
Topclean CYC25
Request Information
Transmitter Liquiline, 2-wire CM72
Endress+Hauser
Transmitter Liquiline, 2-wire CM72
Request Information

Oxygen Sensors & Transmitters

Oxygen sensors and transmitters provide continuous measurement of oxygen in liquids, supporting both dissolved oxygen (DO) control and oxygen monitoring in process and utility systems. The category is positioned for high-accuracy oxygen measurement across industries, reflecting how widely oxygen influences biological performance, corrosion rates, product quality, and treatment efficiency. In many systems, oxygen is a primary control variable rather than a simple indicator, particularly where energy use and compliance are tightly coupled.

Offerings typically include optical and amperometric measurement principles, allowing alignment of technology to application constraints such as response time, maintenance preference, or process conditions. Sensors are paired with transmitters that manage compensation, diagnostics, and signal outputs, and can be implemented within broader digital sensor ecosystems (e.g., Memosens and Liquiline product families). Installation approaches include immersion assemblies for basins and tanks, and flow-through designs for pressurized lines or clean-water loops.

The strongest value proposition is improved control of aeration and oxidation processes with reduced operating cost. In wastewater treatment, DO control directly affects nitrification stability and energy consumption, making reliable measurement critical to balancing compliance and power use. In industrial and power applications, oxygen monitoring helps manage corrosion risk in condensate and boiler feedwater systems. In fermentation and bioprocessing, stable oxygen measurement supports yield and reproducibility where oxygen transfer limitations can drive variability.

Typical applications include activated sludge basins, aeration control loops, and process water systems where oxygen content must be maintained or minimized. Additional deployments include beverage and food processes, life sciences and bioreactors, and utility systems where oxygen ingress indicates leakage or process compromise. Oxygen measurement is also used in environmental monitoring and aquaculture contexts where oxygen availability is directly tied to biological health and process outcomes.

Selection and lifecycle planning should account for fouling potential, required response time, and preferred maintenance approach (e.g., membrane service for amperometric vs. optical sensor handling). Installation geometry, bubble interference, and cleaning access often determine long-term stability more than specification-sheet accuracy. Transmitter and communications requirements typically include analog outputs and/or standard digital protocols for integration into aeration control, alarms, and historian-based optimization programs.

Field Instruments & Controls, Inc. an exclusive authorized representative of sales and service for Endress+Hauser.