Chlorine Sensors & Transmitters

Products for reliable measurement of chlorine and bromine-based disinfectants.

1 - 25 of 25 Products
Transmitter Liquiline, 4-wire CM442
Endress+Hauser
Transmitter Liquiline, 4-wire CM442
Extended Extended
Request Information
Liquiline, 4-wire CM448
Endress+Hauser
Liquiline, 4-wire CM448
Extended Extended
Request Information
Liquiline, 4-wire CM442R
Endress+Hauser
Liquiline, 4-wire CM442R
Extended Extended
Request Information
Liquiline, 4-wire CM444
Endress+Hauser
Liquiline, 4-wire CM444
Extended Extended
Request Information
Memosens CCS51E
Endress+Hauser
Memosens CCS51E
Extended Extended
Request Information
Sensor CCS51
Endress+Hauser
Sensor CCS51
Request Information
Liquisys CCM253
Endress+Hauser
Liquisys CCM253
Request Information
Digital measuring cable Measuring cable CYK10
Endress+Hauser
Digital measuring cable Measuring cable CYK10
Request Information
Memosens CCS58E
Endress+Hauser
Memosens CCS58E
Extended Extended
Request Information
Liquiline, 4-wire CM44P
Endress+Hauser
Liquiline, 4-wire CM44P
Extended Extended
Request Information
Memosens CCS55E
Endress+Hauser
Memosens CCS55E
Extended Extended
Request Information
Liquiline, 4-wire CM448R
Endress+Hauser
Liquiline, 4-wire CM448R
Extended Extended
Request Information
Memocheck CYP02E
Endress+Hauser
Memocheck CYP02E
Request Information
Memosens CCS53E
Endress+Hauser
Memosens CCS53E
Extended Extended
Request Information
Digital measuring cable Memobase CYK20
Endress+Hauser
Digital measuring cable Memobase CYK20
Request Information
Memosens CCS50E
Endress+Hauser
Memosens CCS50E
Extended Extended
Request Information
Flowfit CYA27
Endress+Hauser
Flowfit CYA27
Request Information
Liquiline, 4-wire CM444R
Endress+Hauser
Liquiline, 4-wire CM444R
Extended Extended
Request Information
Liquiline, 4-wire CYY7
Endress+Hauser
Liquiline, 4-wire CYY7
Extended Extended
Request Information
Zero point gel Miscellaneous COY8
Endress+Hauser
Zero point gel Miscellaneous COY8
Request Information
Flexdip CYA112
Endress+Hauser
Flexdip CYA112
Request Information
Memocheck CYP03D
Endress+Hauser
Memocheck CYP03D
Request Information
Measuring cable CYK11
Endress+Hauser
Measuring cable CYK11
Request Information
Liquisys CCM223
Endress+Hauser
Liquisys CCM223
Request Information
Sensor CCS50
Endress+Hauser
Sensor CCS50
Request Information

Chlorine Sensors & Transmitters

Chlorine sensors and transmitters provide continuous measurement of residual disinfectants used for microbial control in water systems. The category includes field sensors and associated transmitters for reliable measurement of chlorine- and bromine-based disinfectants, supporting both control and verification across disinfection processes. Because disinfection performance is sensitive to dose, contact time, and water chemistry, real-time residual measurement becomes a primary feedback signal for stable treatment.

Measurement technologies in this category include amperometric sensors and optical methods, each suited to specific disinfectant regimes and operating conditions. Sensors are paired with transmitters that apply compensation (e.g., temperature), convert signals into standard outputs, and deliver diagnostics for maintenance planning. Platforms may be implemented within digital ecosystems (e.g., Memosens and Liquiline families) and support common industrial protocols for integration into plant networks and control systems.

Continuous disinfection measurement delivers value through tighter chemical control and improved risk management. Maintaining an appropriate residual helps meet microbiological requirements while avoiding overfeed that can drive taste/odor issues, corrosion potential, and unnecessary chemical cost. Trending also supports early detection of process disturbances such as upstream demand shifts, loss of feed, poor mixing, or unexpected contaminant loading, enabling corrective action before off-spec water leaves the process boundary.

Typical applications include drinking-water disinfection, reuse-water systems, and pool-water disinfection, where stable residual control is central to safety and compliance. Additional use cases include food and beverage water management, cooling-water disinfection programs, and industrial process-water circuits where microbial growth impacts quality, fouling, or downstream membrane performance. Sensor selection is often coordinated with the disinfectant chemistry used and the required measurement point (post-contact basin, distribution, or point-of-use).

Successful deployment depends on stable hydraulics at the measurement point and disciplined verification practices. Flow assemblies or bypass loops are commonly used to maintain consistent flow and minimize bubbles and particulate effects. Calibration/verification typically aligns online readings with recognized wet-chemistry checks and documented procedures. Transmitter selection often centers on required outputs, communications, and diagnostics needed to standardize maintenance across multi-site deployments.

Field Instruments & Controls, Inc. an exclusive authorized representative of sales and service for Endress+Hauser.