Liquid Analysis

Comprehensive product range for all analytical parameters.

1 - 48 of 188 Products
Flexdip CYA112
Endress+Hauser
Flexdip CYA112
Request a Quote
Memobase CYZ71D
Endress+Hauser
Memobase CYZ71D
Request a Quote
Liquiline, 4-wire CYY7
Endress+Hauser
Liquiline, 4-wire CYY7
Extended Extended
Request a Quote
Liquiline, 4-wire CM44P
Endress+Hauser
Liquiline, 4-wire CM44P
Extended Extended
Request a Quote
Liquiline, 4-wire CM444
Endress+Hauser
Liquiline, 4-wire CM444
Extended Extended
Request a Quote
Liquiline, 4-wire CM444R
Endress+Hauser
Liquiline, 4-wire CM444R
Extended Extended
Request a Quote
Flowfit CYA27
Endress+Hauser
Flowfit CYA27
Request a Quote
Liquiline, 4-wire CM448R
Endress+Hauser
Liquiline, 4-wire CM448R
Extended Extended
Request a Quote
Measuring cable CYK11
Endress+Hauser
Measuring cable CYK11
Request a Quote
Hand held CYM290
Endress+Hauser
Hand held CYM290
Request a Quote
Flexdip CYH112
Endress+Hauser
Flexdip CYH112
Request a Quote
Transmitter Liquiline, 4-wire CM442
Endress+Hauser
Transmitter Liquiline, 4-wire CM442
Extended Extended
Request a Quote
Liquiline, 4-wire CM442R
Endress+Hauser
Liquiline, 4-wire CM442R
Extended Extended
Request a Quote
Liquiline, 4-wire CM448
Endress+Hauser
Liquiline, 4-wire CM448
Extended Extended
Request a Quote
Digital pH sensor Memosens Wave CPL51E
Endress+Hauser
Digital pH sensor Memosens Wave CPL51E
Fundamental Fundamental
Request a Quote
Converter CYM17
Endress+Hauser
Converter CYM17
Request a Quote
Flowfit CYA21
Endress+Hauser
Flowfit CYA21
Request a Quote
Multi parameter measuring device Hand held CML18
Endress+Hauser
Multi parameter measuring device Hand held CML18
Lean Lean
Request a Quote
Cleanfit CPA875
Endress+Hauser
Cleanfit CPA875
Request a Quote
Assembly CYA251
Endress+Hauser
Assembly CYA251
Request a Quote
Memocheck CYP03D
Endress+Hauser
Memocheck CYP03D
Request a Quote
Assembly CAV01
Endress+Hauser
Assembly CAV01
Extended Extended
Request a Quote
Digital measuring cable Memobase CYK20
Endress+Hauser
Digital measuring cable Memobase CYK20
Request a Quote
Flowfit CPA25
Endress+Hauser
Flowfit CPA25
Lean Lean
Request a Quote
Analyzers, others CA79
Endress+Hauser
Analyzers, others CA79
Extended Extended
Request a Quote
Transmitter Liquiline, 2-wire CM82
Endress+Hauser
Transmitter Liquiline, 2-wire CM82
Request a Quote
Digital pH sensor Orbisint CPS11D
Endress+Hauser
Digital pH sensor Orbisint CPS11D
Extended Extended
Request a Quote
Orbipore CPS96D
Endress+Hauser
Orbipore CPS96D
Request a Quote
Cleanfit CPA474
Endress+Hauser
Cleanfit CPA474
Request a Quote
pH buffer Buffer solution CPY20
Endress+Hauser
pH buffer Buffer solution CPY20
Request a Quote
Dipfit CPA140
Endress+Hauser
Dipfit CPA140
Request a Quote
In-line Photometer OUSAF11
Endress+Hauser
In-line Photometer OUSAF11
Extended Extended
Request a Quote
Analyzers, others CA78
Endress+Hauser
Analyzers, others CA78
Extended Extended
Request a Quote
Transmitter Liquiline, 2-wire CM42
Endress+Hauser
Transmitter Liquiline, 2-wire CM42
Extended Extended
Request a Quote
pH sensor Memosens CPS77E
Endress+Hauser
pH sensor Memosens CPS77E
Extended Extended
Request a Quote
Cleanfit CPA472D
Endress+Hauser
Cleanfit CPA472D
Request a Quote
pH sensor Memosens CPS11E
Endress+Hauser
pH sensor Memosens CPS11E
Extended Extended
Request a Quote
Memosens CPS72E
Endress+Hauser
Memosens CPS72E
Extended Extended
Request a Quote
pH/ORP sensor Memosens CPS96E
Endress+Hauser
pH/ORP sensor Memosens CPS96E
Extended Extended
Request a Quote
Ceragel CPS71D
Endress+Hauser
Ceragel CPS71D
Extended Extended
Request a Quote
Liquiline System CAT860
Endress+Hauser
Liquiline System CAT860
Request a Quote
pH sensor Memosens CPS61E
Endress+Hauser
pH sensor Memosens CPS61E
Extended Extended
Request a Quote
Sensor CCS50
Endress+Hauser
Sensor CCS50
Request a Quote
Digital pH sensor Orbipac CPF81D
Endress+Hauser
Digital pH sensor Orbipac CPF81D
Request a Quote
Cleanfit CPA473
Endress+Hauser
Cleanfit CPA473
Request a Quote
pH sensor Memosens CPS31E
Endress+Hauser
pH sensor Memosens CPS31E
Extended Extended
Request a Quote
Memosens CPF81E
Endress+Hauser
Memosens CPF81E
Extended Extended
Request a Quote
Cleanfit CPA450
Endress+Hauser
Cleanfit CPA450
Request a Quote

Liquid Analysis

Liquid analysis comprises sensors, transmitters, and analyzers used to measure key chemical and physical parameters directly in process streams or supporting utility systems. The discipline is increasingly essential for environmental protection, consistent product quality, process optimization, and safety—especially where liquids must be analyzed continuously across industries such as water, beverages, dairy, chemicals, and pharmaceuticals.

The Endress+Hauser portfolio spans core analytical parameters and complete measuring stations, including pH, conductivity, turbidity, chlorine, oxygen, ORP, TOC/COD/SAC, nutrient measurement, sludge level, process photometers, and microwave transmission measurement, supported by digital sensor technologies. This breadth enables standardization of measurement architecture while tailoring sensing to each critical parameter.

Measurement principles are matched to the parameter: potentiometric methods underpin pH measurement, conductivity can be measured using conductive or toroidal principles, and colorimetric principles support measurement of nutrients, metals, or carbon components. These methods are implemented through instruments designed to meet industrial reliability demands while maintaining measurement integrity over time.

Digitalization is a major enabler in modern liquid analysis. Memosens converts the measured value to a digital signal and transfers it to the transmitter without a contacting connection, supporting resilient signal transmission and more streamlined maintenance approaches. High-precision instruments support improvements in yield, quality, and safety, while modern communication interfaces facilitate integration into plant asset management practices.

Typical applications include disinfection control in drinking water and wastewater, process water quality assurance, CIP/cleaning verification in food and beverage, fermentation and bioprocess monitoring, and chemical process control where tight parameter stability is required. Implementation commonly includes considerations for sampling/installation hardware, calibration workflows, and serviceability to keep analytical loops dependable under real operating conditions.

Field Instruments & Controls, Inc. an exclusive authorized representative of sales and service for Endress+Hauser.